Assessment Year | 2005 |
---|---|
Principal Product | Winches for Vehicles and Cranes |
NAICS | 333923: Overhead Traveling Crane, Hoist, and Monorail System Manufacturing |
SIC | 3531: Construction Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
210,000
ft2
|
Annual Production | 1,600
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $239,108 | 6,043,800 |
kWh
|
$0.040 |
Electricity Demand | $110,165 | 18,299 |
kW-mo/yr
|
$6.02 |
Electricity Fees | $6,431 | - |
|
- |
Natural Gas | $72,510 | 9,315 |
MMBtu
|
$7.78 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $151,759 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $79,678 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3137: Use power during off-peak periods | $1,866 | - | - |
$1,866
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $56,721 | $117,780 |
$45,895
1,158,955
kWh
|
$13,417
-
kW-mo/yr
|
- | - | $(-2,591.0) | |
03 | 2.4227: Use compressor air filters | $4,058 | $920 |
$4,259
107,555
kWh
|
$87
-
kW-mo/yr
|
- | $(-288.0) | - | |
04 | 2.7241: Install outside air damper / economizer on hvac unit | $8,299 | $70 |
$8,299
209,573
kWh
|
- | - | - | - | |
05 | 4.611: Begin a practice of predictive / preventative maintenance | $10,600 | - | - | - | - | $10,600 | - | |
06 | 4.131: Modify process to reduce material use/cost | $70,215 | $3,931 | - |
$325
-
kW-mo/yr
|
$570
-
lb
|
$15,960 | $53,360 | |
TOTAL RECOMMENDED | $151,759 | $122,701 |
$58,453
1,476,083
kWh
|
$15,695
-
kW-mo/yr
|
$570
-
lb
|
$26,272 | $50,769 | ||
TOTAL IMPLEMENTED | $79,678 | $118,770 |
$58,453
1,476,083
kWh
|
$13,504
-
kW-mo/yr
|
- | $10,312 | $(-2,591.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs