ITAC Assessment: GT0588
ITAC logo
ITAC Assessment: GT0588
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Porous Plastics
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 300
Plant Area 175,000
ft2
Annual Production 11,000,000
lb
Production Hrs. Annual 6,864
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $147,149 5,573,271
kWh
Electricity Demand $116,568 13,614
kW-mo/yr
Electricity Fees $39,058 -
Natural Gas $119,680 39,251
MMBtu
Fuel Oil #2 $14,743 2,715
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $125,911 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,484

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Primary Raw Material Savings
01 2.4133: Use most efficient type of electric motors $406 $2,115 $229
8,792
kWh
$154
-
kW-mo/yr
$23 - - - -
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $761 $720 $430
16,413
kWh
$280
-
kW-mo/yr
$51 - - - -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $10,317 $1,450 $5,829
220,692
kWh
$2,884
-
kW-mo/yr
$1,604 - - - -
04 2.7111: Reduce illumination to minimum necessary levels $21,562 $1,890 $12,182
461,313
kWh
$8,132
-
kW-mo/yr
$1,248 - - - -
05 2.2414: Use waste heat from hot flue gases to preheat $7,890 $6,400 - - - $7,890
-
MMBtu
- - -
06 3.5311: Recover and reuse waste material $84,975 $3,860 - - - - $1,225
-
lb
$(-3,750.0) $87,500
TOTAL RECOMMENDED $125,911 $16,435 $18,670
707,210
kWh
$11,450
-
kW-mo/yr
$2,926 $7,890
-
MMBtu
$1,225
-
lb
$(-3,750.0) $87,500
TOTAL IMPLEMENTED $11,484 $4,285 $6,488
245,897
kWh
$3,318
-
kW-mo/yr
$1,678 - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Primary Raw Material Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs