Assessment Year | 2005 |
---|---|
Principal Product | Canned fruit juice and drinks |
NAICS | 311411: Frozen Fruit, Juice, and Vegetable Manufacturing |
SIC | 2037: Frozen Fruits, Fruit Juices, and Vegetables |
Sales Range | $50 M to 100M |
# of Employees | 269 |
Plant Area |
465,000
ft2
|
Annual Production | 227,000,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $514,592 | 14,496,128 |
kWh
|
$0.035 |
Electricity Demand | $229,215 | 27,343 |
kW-mo/yr
|
$8.38 |
Electricity Fees | $35,707 | - |
|
- |
Natural Gas | $926,610 | 150,982 |
MMBtu
|
$6.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $196,858 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $161,012 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2441: Preheat boiler makeup water with waste process heat | $81,171 | $1,436 | - | - |
$81,171
-
MMBtu
|
- | - | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $26,495 | $85,051 | - | - |
$26,495
-
MMBtu
|
- | - | |
03 | 2.4227: Use compressor air filters | $5,346 | $35 |
$4,037
113,743
kWh
|
$1,309
-
kW-mo/yr
|
- | - | - | |
04 | 4.114: Add/modify equipment to improve drying process | $48,000 | $35 | - | - | - | - | $48,000 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $33,796 | $139,341 |
$34,604
974,778
kWh
|
$11,162
-
kW-mo/yr
|
- | $(-11,970.0) | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,489 | $3,283 |
$305
8,585
kWh
|
$99
-
kW-mo/yr
|
- | $1,085 | - | |
07 | 2.7135: Install occupancy sensors | $561 | $975 |
$561
15,808
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $196,858 | $230,156 |
$39,507
1,112,914
kWh
|
$12,570
-
kW-mo/yr
|
$107,666
-
MMBtu
|
$(-10,885.0) | $48,000 | ||
TOTAL IMPLEMENTED | $161,012 | $86,557 |
$4,037
113,743
kWh
|
$1,309
-
kW-mo/yr
|
$107,666
-
MMBtu
|
- | $48,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs