Assessment Year | 1986 |
---|---|
Principal Product | POLYETHYLENE PIPE |
NAICS |
n/a
|
SIC | 3084: Plastics Pipe |
Sales Range | $1 M to 5M |
# of Employees | 17 |
Plant Area |
n/a
|
Annual Production | 7,500,000
lb
|
Production Hrs. Annual | 5,520
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $93,423 | 1,796,014 |
kWh
|
$0.052 |
Natural Gas | $2,233 | 522 |
MMBtu
|
$4.28 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,550 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,663 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $395 | $85 |
$395
4,689
kWh
|
- | |
02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,256 | - |
$1,256
14,361
kWh
|
- | |
03 | 2.2511: Insulate bare equipment | $1,575 | $500 |
$1,575
44,256
kWh
|
- | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $437 | $800 |
$437
8,792
kWh
|
- | |
05 | 4.231: Purchase equipment instead of leasing | $1,887 | $853 | - | $1,887 | |
TOTAL RECOMMENDED | $5,550 | $2,238 |
$3,663
72,098
kWh
|
$1,887 | ||
TOTAL IMPLEMENTED | $3,663 | $1,385 |
$3,663
72,098
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs