| Assessment Year | 2004 |
|---|---|
| Principal Product | Plastic Cups and Plates |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 120 |
| Plant Area |
176,800
ft2
|
| Annual Production | 6,800,000
pieces
|
| Production Hrs. Annual | 8,000
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $981,377 | 26,641,599 |
kWh
|
$0.037 |
| Natural Gas | $25,433 | 3,603 |
MMBtu
|
$7.06 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $415,881 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4224: Upgrade controls on compressors | $19,254 | $25,000 |
$19,254
523,200
kWh
|
- | - | |
| 02 | 2.4227: Use compressor air filters | $4,163 | $130 |
$4,611
125,304
kWh
|
- | $(-448.0) | |
| 03 | 2.2625: Chill water to the highest temperature possible | $10,131 | $11,350 |
$10,131
275,309
kWh
|
- | - | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,342 | $10,540 | n/a |
$3,342
90,817
kWh
|
- | - |
| 05 | 4.426: Modify workload | $378,991 | $200,000 |
$48,991
1,331,287
kWh
|
$330,000 | - | |
| TOTAL RECOMMENDED | $415,881 | $247,020 |
$86,329
2,345,917
kWh
|
$330,000 | $(-448.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs