ITAC Assessment: MO0069
ITAC logo
ITAC Assessment: MO0069
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1992
Principal Product ELECTRICAL CONNECTORS
NAICS
n/a
SIC 3678: Electronic Connectors
Sales Range $100
M
to 500
M
# of Employees 500
Plant Area
n/a
Annual Production 2,400,000
lb
Production Hrs. Annual 6,240
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,545,423 28,359,320
kWh
Natural Gas $240,240 77,161
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $19,922 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,314

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.4133: Use most efficient type of electric motors $2,525 $29,000 $2,525
46,307
kWh
- -
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $3,501 $450 $3,501
64,185
kWh
- -
03 2.1233: Analyze flue gas for proper air/fuel ratio $3,641 $5,145 - $3,641
-
MMBtu
-
04 2.4312: Improve lubrication practices $4,967 $587 $4,967
91,149
kWh
- -
05 2.4221: Install compressor air intakes in coolest locations $2,541 $1,300 $2,541
46,600
kWh
- -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $1,853 $760 $2,074
38,101
kWh
- $(-221.0)
07 2.7142: Utilize higher efficiency lamps and/or ballasts $894 $3,500 $894
16,413
kWh
- -
TOTAL RECOMMENDED $19,922 $40,742 $16,502
302,755
kWh
$3,641
-
MMBtu
$(-221.0)
TOTAL IMPLEMENTED $11,314 $35,010 $11,535
211,606
kWh
- $(-221.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs