| Assessment Year | 2003 |
|---|---|
| Principal Product | Instrumentation & Control Equipment |
| NAICS | 334513: Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial |
| SIC | 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products |
| Sales Range | $50 M to 100M |
| # of Employees | 300 |
| Plant Area |
187,000
ft2
|
| Annual Production | 1,500,000
pieces
|
| Production Hrs. Annual | 5,148
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $175,399 | 3,642,320 |
kWh
|
$0.048 |
| Electricity Fees | $(-5,246.0) | - |
|
- |
| Natural Gas | $26,305 | 4,300 |
MMBtu
|
$6.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $38,293 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $25,063 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.6232: Install set-back timers | $4,895 | $664 | - |
$4,895
-
kW-mo/yr
|
- | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,602 | - |
$2,602
58,212
kWh
|
- | - | - | |
| 03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,094 | $6,844 | - |
$2,094
-
kW-mo/yr
|
- | - | |
| 04 | 2.7241: Install outside air damper / economizer on hvac unit | $2,748 | $3,480 |
$2,748
61,488
kWh
|
- | - | - | |
| 05 | 4.611: Begin a practice of predictive / preventative maintenance | $10,600 | - | - | - | $10,600 | - | |
| 06 | 2.7135: Install occupancy sensors | $1,398 | $1,374 |
$1,398
31,278
kWh
|
- | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,550 | $13,880 |
$3,912
87,516
kWh
|
$886
-
kW-mo/yr
|
- | $752 | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,270 | $1,048 |
$608
13,605
kWh
|
$274
-
kW-mo/yr
|
- | $388 | |
| 09 | 2.7425: Clean or color roof to reduce solar load | $7,136 | $32,000 | n/a |
$7,136
159,650
kWh
|
- | - | - |
| TOTAL RECOMMENDED | $38,293 | $59,290 |
$18,404
411,749
kWh
|
$8,149
-
kW-mo/yr
|
$10,600 | $1,140 | ||
| TOTAL IMPLEMENTED | $25,063 | $19,072 |
$7,268
162,609
kWh
|
$6,055
-
kW-mo/yr
|
$10,600 | $1,140 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs