Assessment Year | 2000 |
---|---|
Principal Product | Metal Cutting Band Saw |
NAICS |
n/a
|
SIC | 3541: Machine Tools, Metal Cutting Types |
Sales Range | $5 M to 10M |
# of Employees | 310 |
Plant Area |
140,000
ft2
|
Annual Production | 720
pieces
|
Production Hrs. Annual | 6,552
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $42,145 | 2,351,700 |
kWh
|
$0.018 |
Electricity Demand | $58,501 | - |
|
- |
Natural Gas | $20,966 | 5,039 |
MMBtu
|
$4.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $263,910 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,870 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,935 | $800 |
$9,364
520,223
kWh
|
$571
-
kW-mo/yr
|
- | - | - | |
02 | 2.7232: Replace existing hvac unit with high efficiency model | $8,177 | $13,490 | - | - |
$8,177
-
MMBtu
|
- | - | |
03 | 2.7145: Install skylights | $3,419 | $2,000 |
$1,041
57,737
kWh
|
$2,378
-
kW-mo/yr
|
- | - | - | |
04 | 4.446: Automate finishing process | $137,280 | $200,000 | - | - | - | - | $137,280 | |
05 | 2.7135: Install occupancy sensors | $3,339 | $860 |
$2,098
33,705
kWh
|
$2,053
-
kW-mo/yr
|
$(-812.0)
-
MMBtu
|
- | - | |
06 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $1,028 | - | - | - | - |
$1,028
-
lb
|
- | |
07 | 2.7141: Lower light fixtures in high ceiling areas | $81,900 | $11,250 | - | - | - | - | $81,900 | |
08 | 2.7111: Reduce illumination to minimum necessary levels | $10,512 | $561 |
$5,556
235,346
kWh
|
$4,956
-
kW-mo/yr
|
- | - | - | |
09 | 4.425: Eliminate/reduce redundant inspections | $8,320 | - | - | - | - | - | $8,320 | |
TOTAL RECOMMENDED | $263,910 | $228,961 |
$18,059
847,011
kWh
|
$9,958
-
kW-mo/yr
|
$7,365
-
MMBtu
|
$1,028
-
lb
|
$227,500 | ||
TOTAL IMPLEMENTED | $24,870 | $17,150 |
$12,503
611,665
kWh
|
$5,002
-
kW-mo/yr
|
$7,365
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs