| Assessment Year | 1999 |
|---|---|
| Principal Product | Aerospace electronics |
| NAICS |
n/a
|
| SIC | 3679: Electronic Components, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 138 |
| Plant Area |
86,000
ft2
|
| Annual Production | 15
units
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $59,048 | 1,679,953 |
kWh
|
$0.035 |
| Electricity Demand | $26,530 | - |
|
- |
| Electricity Fees | $3,300 | - |
|
- |
| Natural Gas | $3,150 | 475 |
MMBtu
|
$6.63 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,437 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,807 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7232: Replace existing hvac unit with high efficiency model | $840 | $1,900 |
$840
23,447
kWh
|
- | |
| 02 | 2.7144: Install spectral reflectors / delamp | $884 | $96 |
$884
13,189
kWh
|
- | |
| 03 | 2.7144: Install spectral reflectors / delamp | $746 | $225 |
$746
11,137
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $599 | $1,251 |
$599
13,775
kWh
|
- | |
| 05 | 2.6232: Install set-back timers | $2,191 | $4,860 |
$2,191
61,254
kWh
|
- | |
| 06 | 2.6232: Install set-back timers | $1,177 | $1,116 | - |
$1,177
-
MMBtu
|
|
| TOTAL RECOMMENDED | $6,437 | $9,448 |
$5,260
122,802
kWh
|
$1,177
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $2,807 | $1,437 |
$1,630
24,326
kWh
|
$1,177
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||