| Assessment Year | 1999 |
|---|---|
| Principal Product | Transformers |
| NAICS |
n/a
|
| SIC | 3612: Power, Distribution, and Specialty Transformers |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
80,000
ft2
|
| Annual Production | 72
pieces
|
| Production Hrs. Annual | 3,840
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $65,584 | 1,179,660 |
kWh
|
$0.056 |
| Electricity Demand | $49,130 | - |
|
- |
| Electricity Fees | $1,098 | - |
|
- |
| Natural Gas | $21,429 | 8,745 |
MMBtu
|
$2.45 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $57,502 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $726 | $2,286 | n/a |
$726
24,326
kWh
|
- | - | - | - | - |
| 02 | 4.821: Pay bills on time to avoid late fees | $333 | - | n/a | - | - | - | - | - | $333 |
| 03 | 4.424: Improve space comfort conditioning | $40,159 | $2,880 | n/a | - | - | - | - | $40,159 | - |
| 04 | 3.1175: Use a different or recycled raw material | $12,000 | $17,070 | n/a | - | - |
$12,000
-
gal
|
- | - | - |
| 05 | 2.1116: Improve combustion control capability | $665 | - | n/a | - |
$665
-
MMBtu
|
- | - | - | - |
| 06 | 3.5313: Increase amount of waste recovered for resale | $400 | - | n/a | - | - | - |
$400
-
lb
|
- | - |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $519 | $150 | n/a |
$519
9,379
kWh
|
- | - | - | - | - |
| 08 | 3.5311: Recover and reuse waste material | $2,700 | - | n/a | - | - | - |
$2,700
-
lb
|
- | - |
| TOTAL RECOMMENDED | $57,502 | $22,386 |
$1,245
33,705
kWh
|
$665
-
MMBtu
|
$12,000
-
gal
|
$3,100
-
lb
|
$40,159 | $333 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs