ITAC Assessment: OK0569
ITAC logo
ITAC Assessment: OK0569
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1999
Principal Product Oil Field Chemicals
NAICS
n/a
SIC 2819: Industrial Inorganic Chemicals, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 110
Plant Area 1,554,000
ft2
Annual Production 37,800
thousand feet
Production Hrs. Annual 8,760
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $152,626 10,494,432
kWh
Electricity Demand $67,173 -
Electricity Fees $3,150 -
Natural Gas $334,402 118,787
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $276,140 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $136,289

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Other Liquid (non-haz) Savings Other Liquid (haz) Savings Administrative Changes Savings
01 3.4151: Minimize water usage $127,756 $296,160 - - $127,756
-
gal
-
02 3.3125: Use distillation, evaporation to remove contaminants $74,871 $125,000 - $74,871
-
gal
- -
03 2.2135: Repair and eliminate steam leaks $32,085 $3,300 $32,085
3,121,043
kWh
- - -
04 2.4133: Use most efficient type of electric motors $19,442 $26,944 $19,442
598,183
kWh
- - -
05 4.122: Develop standard procedures to improve internal yields $9,062 - - - - $9,062
06 2.2136: Install / repair insulation on steam lines $5,140 $13,288 $5,140
535,170
kWh
- - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $2,918 $6,195 $2,918
36,928
kWh
- - -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $1,833 $3,098 $1,833
57,151
kWh
- - -
09 2.7134: Use photocell controls $1,193 $683 $1,193
61,254
kWh
- - -
10 2.7135: Install occupancy sensors $945 $656 $945
23,447
kWh
- - -
11 2.6232: Install set-back timers $895 $420 $895
93,200
kWh
- - -
TOTAL RECOMMENDED $276,140 $475,744 $64,451
4,526,376
kWh
$74,871
-
gal
$127,756
-
gal
$9,062
TOTAL IMPLEMENTED $136,289 $177,825 $61,418
4,348,475
kWh
$74,871
-
gal
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Other Liquid (non-haz) Savings Other Liquid (haz) Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs