| Assessment Year | 2019 |
|---|---|
| Principal Product | Wastewater/Sewage Treatment |
| NAICS | 221320: Sewage Treatment Facilities |
| SIC | 4952: Sewerage Systems |
| Sales Range | less than $500 k |
| # of Employees | 21 |
| Plant Area |
780,000
ft2
|
| Annual Production | 5,475,000
Tgal
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $563,344 | 9,996,000 |
kWh
|
$0.056 |
| Electricity Demand | $98,880 | 24,000 |
kW-mo/yr
|
$4.12 |
| Natural Gas | $44,864 | 7,187 |
MMBtu
|
$6.24 |
| TOTAL YEARLY COSTS | $707,088 | |||
| RECOMMENDED SAVINGS* | $205,464 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $1,297 | $6 |
$1,297
23,020
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $25,814 | $6,317 |
$23,373
414,736
kWh
|
$2,441
-
kW-mo/yr
|
|
| 03 | 2.7124: Make a practice of turning off lights when not needed | $1,753 | $500 |
$1,753
31,098
kWh
|
- | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $458 | $158 |
$458
8,130
kWh
|
- | |
| 05 | 2.4322: Use or replace with energy efficient substitutes | $89,345 | $41,575 |
$81,212
1,441,020
kWh
|
$8,133
-
kW-mo/yr
|
|
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $86,774 | $49,800 |
$86,774
1,539,727
kWh
|
- | |
| 07 | 2.7135: Install occupancy sensors | $23 | $25 |
$23
400
kWh
|
- | |
| TOTAL RECOMMENDED | $205,464 | $98,381 |
$194,890
3,458,131
kWh
|
$10,574
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs