Assessment Year 1999
Principal Product Blow molded equipment
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 140
Plant Area 185,000
ft2
Annual Production 18,000,000
lb
Production Hrs. Annual 8,568
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $262,695 11,125,440
kWh
Electricity Demand $172,163 -
Electricity Fees $(-21,982.0) -
Natural Gas $35,967 6,818
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $152,281 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $136,861

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings
01 4.444: Install system to collect scrap $68,913 $7,650 $648
30,875
kWh
- - - - $68,265
02 2.8121: Apply for tax-free status for energy purchases $29,064 - - - $29,064 - - -
03 2.4322: Use or replace with energy efficient substitutes $15,420 $68,000 - - - $15,420
-
MMBtu
- -
04 2.2511: Insulate bare equipment $14,128 $11,350 $14,128
605,510
kWh
- - - - -
05 2.4221: Install compressor air intakes in coolest locations $11,432 $4,500 $7,122
339,097
kWh
$4,310
-
kW-mo/yr
- - - -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,164 $320 $3,179
156,213
kWh
$1,985
-
kW-mo/yr
- - - -
07 2.7145: Install skylights $4,523 $5,340 $2,818
134,232
kWh
$1,705
-
kW-mo/yr
- - - -
08 3.5313: Increase amount of waste recovered for resale $3,637 $7,900 - - - - $3,637
-
lb
-
TOTAL RECOMMENDED $152,281 $105,060 $27,895
1,265,927
kWh
$8,000
-
kW-mo/yr
$29,064 $15,420
-
MMBtu
$3,637
-
lb
$68,265
TOTAL IMPLEMENTED $136,861 $37,060 $27,895
1,265,927
kWh
$8,000
-
kW-mo/yr
$29,064 - $3,637
-
lb
$68,265
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs