Assessment Year | 1997 |
---|---|
Principal Product | speakers/amplifiers |
NAICS |
n/a
|
SIC | 3651: Household Audio and Video Equipment |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
250,000
ft2
|
Annual Production | 360,000
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $80,276 | 2,604,045 |
kWh
|
$0.031 |
Electricity Demand | $64,026 | 7,434 |
kW-mo/yr
|
$8.61 |
Natural Gas | $17,599 | 4,806 |
MMBtu
|
$3.66 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $74,467 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.2176: Increase use of automation | $66,300 | $200,000 | - | - | - | - | $66,300 | |
02 | 3.8142: Distill contaminated solvents for reuse | $5,370 | $1,320 | - | - |
$(-66.0)
-
MMBtu
|
$5,436
-
gal
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,798 | $9,384 |
$580
22,860
kWh
|
$1,218
-
kW-mo/yr
|
- | - | - | |
04 | 2.1123: Install automatic stack damper | $679 | $847 | - | - |
$679
-
MMBtu
|
- | - | |
05 | 2.7135: Install occupancy sensors | $220 | $622 |
$220
8,792
kWh
|
- | - | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $100 | $161 |
$100
4,103
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $74,467 | $212,334 |
$900
35,755
kWh
|
$1,218
-
kW-mo/yr
|
$613
-
MMBtu
|
$5,436
-
gal
|
$66,300 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs