Assessment Year | 1995 |
---|---|
Principal Product | Custom printed envelope |
NAICS |
n/a
|
SIC | 2677: Envelopes |
Sales Range | $10 M to 50M |
# of Employees | 101 |
Plant Area |
117,500
ft2
|
Annual Production | 750,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $128,469 | 2,626,905 |
kWh
|
$0.049 |
Natural Gas | $6,162 | 1,153 |
MMBtu
|
$5.34 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,571 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,968 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $9,273 | $20,856 |
$9,273
189,332
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,961 | $18,975 |
$3,961
80,891
kWh
|
|
03 | 2.4221: Install compressor air intakes in coolest locations | $642 | $1,638 |
$642
13,189
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $305 | $356 |
$305
2,345
kWh
|
|
05 | 2.7135: Install occupancy sensors | $218 | $520 |
$218
4,689
kWh
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $172 | $102 |
$172
3,517
kWh
|
|
TOTAL RECOMMENDED | $14,571 | $42,447 |
$14,571
293,963
kWh
|
||
TOTAL IMPLEMENTED | $9,968 | $21,834 |
$9,968
199,883
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs