| Assessment Year | 1994 |
|---|---|
| Principal Product | Fabric covers |
| NAICS |
n/a
|
| SIC | 2394: Canvas and Related Products |
| Sales Range | $10 M to 50M |
| # of Employees | 220 |
| Plant Area |
110,000
ft2
|
| Annual Production | 100,000
pieces
|
| Production Hrs. Annual | 7,280
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $138,371 | 1,775,791 |
kWh
|
$0.078 |
| Natural Gas | $11,668 | 2,384 |
MMBtu
|
$4.89 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,952 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,091 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,087 | $6,264 |
$2,087
31,067
kWh
|
- | |
| 02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,150 | $6,790 |
$2,943
48,945
kWh
|
$(-793.0)
-
MMBtu
|
|
| 03 | 2.7241: Install outside air damper / economizer on hvac unit | $1,624 | $4,901 |
$1,624
64,478
kWh
|
- | |
| 04 | 2.7131: Add area lighting switches | $861 | $1,272 |
$861
33,998
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $513 | $997 |
$513
3,810
kWh
|
- | |
| 06 | 2.2437: Recover waste heat from equipment | $419 | $544 | - |
$419
-
MMBtu
|
|
| 07 | 2.4221: Install compressor air intakes in coolest locations | $298 | $655 |
$298
6,155
kWh
|
- | |
| TOTAL RECOMMENDED | $7,952 | $21,423 |
$8,326
188,453
kWh
|
$(-374.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $2,091 | $3,468 |
$1,672
43,963
kWh
|
$419
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs