Assessment Year | 1994 |
---|---|
Principal Product | Fuel filter cartridges |
NAICS |
n/a
|
SIC | 3569: General Industrial Machinery and Equipment, Not Elsewhere |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
67,500
ft2
|
Annual Production | 360,000
pieces
|
Production Hrs. Annual | 5,200
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $78,967 | 1,256,448 |
kWh
|
$0.063 |
Natural Gas | $49,977 | 12,534 |
MMBtu
|
$3.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,796 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,737 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,592 | $19,151 |
$11,592
197,538
kWh
|
- | |
02 | 2.6232: Install set-back timers | $2,059 | $1,200 |
$2,059
91,442
kWh
|
- | |
03 | 2.2136: Install / repair insulation on steam lines | $724 | $1,524 | - |
$724
-
MMBtu
|
|
04 | 2.7224: Reduce space conditioning during non-working hours | $342 | - | - |
$342
-
MMBtu
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $79 | $395 |
$79
2,345
kWh
|
- | |
TOTAL RECOMMENDED | $14,796 | $22,270 |
$13,730
291,325
kWh
|
$1,066
-
MMBtu
|
||
TOTAL IMPLEMENTED | $12,737 | $21,070 |
$11,671
199,883
kWh
|
$1,066
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs