Assessment Year | 1994 |
---|---|
Principal Product | Bottles of beverage |
NAICS |
n/a
|
SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
Sales Range | $10 M to 50M |
# of Employees | 89 |
Plant Area |
150,000
ft2
|
Annual Production | 11,000,000
pieces
|
Production Hrs. Annual | 5,200
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $183,633 | 4,082,943 |
kWh
|
$0.045 |
Natural Gas | $80,063 | 21,516 |
MMBtu
|
$3.72 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,419 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $28,897 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.8112: Combine utility meters | $7,983 | $1,000 | - | - | $7,983 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,384 | $14,592 |
$4,384
72,392
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,869 | $4,479 |
$1,869
33,998
kWh
|
- | - | |
04 | 2.4133: Use most efficient type of electric motors | $3,037 | $5,851 |
$3,037
54,513
kWh
|
- | - | |
05 | 2.7224: Reduce space conditioning during non-working hours | $2,765 | $2,266 | - |
$2,765
-
MMBtu
|
- | |
06 | 2.2437: Recover waste heat from equipment | $2,659 | $5,600 |
$2,659
209,555
kWh
|
- | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $970 | $570 |
$970
23,154
kWh
|
- | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,225 | $6,508 |
$3,225
69,168
kWh
|
- | - | |
09 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $9,128 | $3,594 |
$15,475
428,781
kWh
|
$(-6,347.0)
-
MMBtu
|
- | |
10 | 2.8121: Apply for tax-free status for energy purchases | $5,412 | - | - | - | $5,412 | |
11 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,987 | $3,000 | - |
$2,987
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $44,419 | $47,460 |
$31,619
891,561
kWh
|
$(-595.0)
-
MMBtu
|
$13,395 | ||
TOTAL IMPLEMENTED | $28,897 | $35,430 |
$12,515
230,071
kWh
|
$2,987
-
MMBtu
|
$13,395 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs