| Assessment Year | 1994 |
|---|---|
| Principal Product | Cans of beverage |
| NAICS |
n/a
|
| SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
| Sales Range | $10 M to 50M |
| # of Employees | 75 |
| Plant Area |
150,000
ft2
|
| Annual Production | 12,000,000
pieces
|
| Production Hrs. Annual | 7,280
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $215,570 | 4,793,083 |
kWh
|
$0.045 |
| Natural Gas | $62,709 | 18,071 |
MMBtu
|
$3.47 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $40,790 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $20,000 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.8112: Combine utility meters | $2,389 | - | - | - | $2,389 | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,132 | $14,113 |
$4,132
66,530
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $585 | $1,113 |
$585
13,189
kWh
|
- | - | |
| 04 | 2.4133: Use most efficient type of electric motors | $9,215 | $4,859 |
$9,215
54,220
kWh
|
- | - | |
| 05 | 2.7224: Reduce space conditioning during non-working hours | $1,742 | $1,442 | - |
$1,742
-
MMBtu
|
- | |
| 06 | 2.2437: Recover waste heat from equipment | $5,203 | $12,800 |
$5,203
439,332
kWh
|
- | - | |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $1,008 | $276 |
$1,008
26,671
kWh
|
- | - | |
| 08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,149 | $3,720 |
$3,149
79,132
kWh
|
- | - | |
| 09 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $9,128 | $3,594 |
$15,475
428,781
kWh
|
$(-6,347.0)
-
MMBtu
|
- | |
| 10 | 2.8121: Apply for tax-free status for energy purchases | $4,239 | - | - | - | $4,239 | |
| TOTAL RECOMMENDED | $40,790 | $41,917 |
$38,767
1,107,855
kWh
|
$(-4,605.0)
-
MMBtu
|
$6,628 | ||
| TOTAL IMPLEMENTED | $20,000 | $8,855 |
$13,372
160,023
kWh
|
- | $6,628 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs