ITAC Assessment: OK0435
ITAC logo
ITAC Assessment: OK0435
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1994
Principal Product Interior furniture for Aircraft
NAICS
n/a
SIC 2511: Wood Household Furniture, Except Upholstered
Sales Range $10
M
to 50
M
# of Employees 175
Plant Area 70,000
ft2
Annual Production 0
units
Production Hrs. Annual 3,432
hrs
Location (State) Kansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $94,887 956,917
kWh
Natural Gas $20,562 4,292
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $11,916 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4324: Replace hydraulic / pneumatic equipment with electric equipment $2,102 $7,500 $2,102
33,705
kWh
02 2.4221: Install compressor air intakes in coolest locations $374 $739 $374
5,862
kWh
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $734 - $734
13,189
kWh
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,461 $3,216 $1,461
7,913
kWh
05 2.7142: Utilize higher efficiency lamps and/or ballasts $3,330 $6,068 $3,330
18,757
kWh
06 2.7111: Reduce illumination to minimum necessary levels $2,031 - $2,031
10,258
kWh
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $555 - $555
6,155
kWh
08 2.7224: Reduce space conditioning during non-working hours $671 $450 $671
41,032
kWh
09 2.4133: Use most efficient type of electric motors $658 $1,539 $658
10,551
kWh
TOTAL RECOMMENDED $11,916 $19,512 $11,916
147,422
kWh
TOTAL IMPLEMENTED - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs