Assessment Year | 1994 |
---|---|
Principal Product | Grills, Diffusers and registers for HVAC applications |
NAICS |
n/a
|
SIC | 3446: Architectural and Ornamental Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 390 |
Plant Area |
189,000
ft2
|
Annual Production | 2,400,000
pieces
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $208,398 | 3,483,001 |
kWh
|
$0.060 |
Natural Gas | $71,731 | 24,476 |
MMBtu
|
$2.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,042 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,860 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,860 | $4,250 |
$1,860
18,464
kWh
|
|
02 | 2.2437: Recover waste heat from equipment | $1,482 | $1,440 |
$1,482
126,026
kWh
|
|
03 | 2.4221: Install compressor air intakes in coolest locations | $1,859 | $888 |
$1,859
32,532
kWh
|
|
04 | 2.4133: Use most efficient type of electric motors | $6,960 | $10,233 |
$6,960
122,216
kWh
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,881 | - |
$4,881
85,580
kWh
|
|
TOTAL RECOMMENDED | $17,042 | $16,811 |
$17,042
384,818
kWh
|
||
TOTAL IMPLEMENTED | $1,860 | $4,250 |
$1,860
18,464
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs