Assessment Year | 1992 |
---|---|
Principal Product | MICROWAVE ABSORBERS |
NAICS |
n/a
|
SIC | 3821: Laboratory Apparatus and Furniture |
Sales Range | $1 M to 5M |
# of Employees | 42 |
Plant Area |
n/a
|
Annual Production | 50,000
pieces
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $110,620 | 1,759,379 |
kWh
|
$0.063 |
Natural Gas | $46,345 | 16,348 |
MMBtu
|
$2.83 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $25,599 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,268 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,850 | $73,884 |
$19,796
375,440
kWh
|
$(-1,946.0)
-
MMBtu
|
- | |
02 | 2.7123: Keep lamps and reflectors clean | $2,101 | $4,704 |
$2,268
41,325
kWh
|
$(-167.0)
-
MMBtu
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $302 | - |
$332
9,379
kWh
|
- | $(-30.0) | |
04 | 2.4221: Install compressor air intakes in coolest locations | $472 | $444 |
$472
13,482
kWh
|
- | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $966 | $1,880 |
$966
14,068
kWh
|
- | - | |
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $3,908 | $4,518 |
$3,908
-
kWh
|
- | - | |
TOTAL RECOMMENDED | $25,599 | $85,430 |
$27,742
453,694
kWh
|
$(-2,113.0)
-
MMBtu
|
$(-30.0) | ||
TOTAL IMPLEMENTED | $1,268 | $1,880 |
$1,298
23,447
kWh
|
- | $(-30.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs