Assessment Year | 1991 |
---|---|
Principal Product | READY-MIX CONCRETE |
NAICS |
n/a
|
SIC | 3273: Ready-Mixed Concrete |
Sales Range | $10 M to 50M |
# of Employees | 20 |
Plant Area |
n/a
|
Annual Production | 101
thousand feet
|
Production Hrs. Annual | 2,860
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $15,174 | 213,365 |
kWh
|
$0.071 |
Natural Gas | $6,446 | 1,781 |
MMBtu
|
$3.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,512 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,512 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,500 | - |
$2,500
38,980
kWh
|
- | |
02 | 2.7261: Install timers and/or thermostats | $1,267 | $400 | - |
$1,267
-
MMBtu
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $292 | - |
$292
4,396
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $321 | $759 |
$321
4,396
kWh
|
- | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $132 | - |
$132
2,052
kWh
|
- | |
TOTAL RECOMMENDED | $4,512 | $1,159 |
$3,245
49,824
kWh
|
$1,267
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,512 | $1,159 |
$3,245
49,824
kWh
|
$1,267
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs