| Assessment Year | 1991 |
|---|---|
| Principal Product | DENIM JEANS |
| NAICS |
n/a
|
| SIC | 2326: Men's and Boys' Work Clothing |
| Sales Range | $10 M to 50M |
| # of Employees | 300 |
| Plant Area |
n/a
|
| Annual Production | 4,200,000
pieces
|
| Production Hrs. Annual | 2,025
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $78,454 | 1,350,234 |
kWh
|
$0.058 |
| Natural Gas | $4,357 | 906 |
MMBtu
|
$4.81 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,434 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,434 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $857 | - |
$857
14,361
kWh
|
- | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,919 | - |
$3,949
66,530
kWh
|
- | $(-1,030.0) | |
| 03 | 2.2437: Recover waste heat from equipment | $1,122 | $866 | - |
$1,122
-
MMBtu
|
- | |
| 04 | 2.7261: Install timers and/or thermostats | $1,923 | $1,500 | - |
$1,923
-
MMBtu
|
- | |
| 05 | 2.7123: Keep lamps and reflectors clean | $613 | - |
$541
9,086
kWh
|
- | $72 | |
| TOTAL RECOMMENDED | $7,434 | $2,366 |
$5,347
89,977
kWh
|
$3,045
-
MMBtu
|
$(-958.0) | ||
| TOTAL IMPLEMENTED | $7,434 | $2,366 |
$5,347
89,977
kWh
|
$3,045
-
MMBtu
|
$(-958.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs