Assessment Year | 1990 |
---|---|
Principal Product | FISHING REELS |
NAICS |
n/a
|
SIC | 3949: Sporting and Athletic Goods, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
n/a
|
Annual Production | 5,500,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $181,647 | 3,516,999 |
kWh
|
$0.052 |
Natural Gas | $8,339 | 2,409 |
MMBtu
|
$3.46 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,200 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,060 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $880 | $355 |
$880
13,189
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $805 | $135 |
$805
15,826
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $224 | - |
$384
12,896
kWh
|
- | $(-160.0) | |
04 | 2.3511: Use plant owned transformers or lease transformers | $10,140 | $17,000 |
$10,140
-
kWh
|
- | - | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $5,151 | $1,200 |
$2,865
102,872
kWh
|
$2,286
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $17,200 | $18,690 |
$15,074
144,783
kWh
|
$2,286
-
MMBtu
|
$(-160.0) | ||
TOTAL IMPLEMENTED | $7,060 | $1,690 |
$4,934
144,783
kWh
|
$2,286
-
MMBtu
|
$(-160.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs