Assessment Year | 1988 |
---|---|
Principal Product | AIRCRAFT FILTERS, ETC. |
NAICS |
n/a
|
SIC | 3569: General Industrial Machinery and Equipment, Not Elsewhere |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 0
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $182,953 | 3,832,943 |
kWh
|
$0.048 |
Natural Gas | $42,272 | 13,306 |
MMBtu
|
$3.18 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,309 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,976 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $15,713 | $3,089 | - |
$15,713
-
MMBtu
|
- | |
02 | 2.7221: Lower temperature during the winter season and vice-versa | $2,723 | - | - |
$2,723
-
MMBtu
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $495 | - |
$535
17,878
kWh
|
- | $(-40.0) | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,786 | - |
$3,786
127,491
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $982 | $840 |
$982
18,171
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,610 | $9,800 |
$2,542
70,047
kWh
|
- | $68 | |
TOTAL RECOMMENDED | $26,309 | $13,729 |
$7,845
233,587
kWh
|
$18,436
-
MMBtu
|
$28 | ||
TOTAL IMPLEMENTED | $20,976 | $3,929 |
$5,303
163,540
kWh
|
$15,713
-
MMBtu
|
$(-40.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs