Assessment Year | 1988 |
---|---|
Principal Product | REPAIR ELECTRIC MOTORS |
NAICS |
n/a
|
SIC | 3699: Electrical Machinery, Equipment, and Supplies, Not Elsewhere |
Sales Range | $1 M to 5M |
# of Employees | 40 |
Plant Area |
n/a
|
Annual Production | 1,200
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $43,493 | 583,822 |
kWh
|
$0.074 |
Natural Gas | $30,364 | 7,737 |
MMBtu
|
$3.92 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,973 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,973 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $2,293 | $2,800 | - |
$2,293
-
MMBtu
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,639 | - |
$1,739
23,447
kWh
|
- | $(-100.0) | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $626 | $1,500 |
$536
7,327
kWh
|
- | $90 | |
04 | 2.8114: Change rate schedules or other changes in utility service | $9,415 | - |
$9,415
-
kWh
|
- | - | |
TOTAL RECOMMENDED | $13,973 | $4,300 |
$11,690
30,774
kWh
|
$2,293
-
MMBtu
|
$(-10.0) | ||
TOTAL IMPLEMENTED | $13,973 | $4,300 |
$11,690
30,774
kWh
|
$2,293
-
MMBtu
|
$(-10.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs