Assessment Year | 1987 |
---|---|
Principal Product | STEEL FABRICATION |
NAICS |
n/a
|
SIC | 3441: Fabricated Structural Metal |
Sales Range | $5 M to 10M |
# of Employees | 64 |
Plant Area |
n/a
|
Annual Production | 3,500,000
lb
|
Production Hrs. Annual | 2,850
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $44,511 | 504,103 |
kWh
|
$0.088 |
Natural Gas | $12,211 | 3,742 |
MMBtu
|
$3.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,328 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,328 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $610 | $185 |
$668
13,189
kWh
|
$(-58.0)
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $333 | $547 |
$333
3,517
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,012 | $2,117 |
$1,072
11,137
kWh
|
$(-60.0)
-
MMBtu
|
|
04 | 2.7261: Install timers and/or thermostats | $6,373 | $456 |
$1,154
16,999
kWh
|
$5,219
-
MMBtu
|
|
TOTAL RECOMMENDED | $8,328 | $3,305 |
$3,227
44,842
kWh
|
$5,101
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,328 | $3,305 |
$3,227
44,842
kWh
|
$5,101
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs