Assessment Year | 1987 |
---|---|
Principal Product | SONIC EQUIPMENT |
NAICS |
n/a
|
SIC | 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products |
Sales Range | $1 M to 5M |
# of Employees | 32 |
Plant Area |
n/a
|
Annual Production | 2,750,000
pieces
|
Production Hrs. Annual | 2,535
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $19,680 | 245,018 |
kWh
|
$0.080 |
Natural Gas | $3,297 | 718 |
MMBtu
|
$4.59 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,002 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $987 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $100 | $62 |
$100
1,465
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $70 | $146 |
$70
1,172
kWh
|
- | |
03 | 2.3191: Use demand controller or load shedder | $2,542 | $510 |
$2,542
-
kWh
|
- | |
04 | 2.7231: Use radiant heater for spot heating | $817 | $3,200 | - |
$817
-
MMBtu
|
|
05 | 2.7261: Install timers and/or thermostats | $473 | $450 | - |
$473
-
MMBtu
|
|
TOTAL RECOMMENDED | $4,002 | $4,368 |
$2,712
2,637
kWh
|
$1,290
-
MMBtu
|
||
TOTAL IMPLEMENTED | $987 | $3,408 |
$170
2,637
kWh
|
$817
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs