ITAC Assessment: OK0197
ITAC logo
ITAC Assessment: OK0197
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1986
Principal Product CORRUGATED SHIPPING BOX
NAICS
n/a
SIC 2653: Corrugated and Solid Fiber Boxes
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area
n/a
Annual Production 500,000
thousand feet
Production Hrs. Annual 4,420
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $158,176 3,289,859
kWh
Natural Gas $137,674 38,731
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $23,097 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $19,774

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.1242: Minimize boiler blowdown with better feedwater treatment $2,964 $3,200 - $2,964
-
MMBtu
-
02 2.2122: Install / repair insulation on condensate lines $369 $360 - $369
-
MMBtu
-
03 2.1233: Analyze flue gas for proper air/fuel ratio $2,954 $1,500 - $2,954
-
MMBtu
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $547 $80 $547
14,947
kWh
- -
05 2.4312: Improve lubrication practices $11,758 - $12,958
245,311
kWh
- $(-1,200.0)
06 2.7142: Utilize higher efficiency lamps and/or ballasts $817 $782 $893
16,706
kWh
$(-76.0)
-
MMBtu
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,696 $2,411 $1,415
26,671
kWh
- $281
08 2.7444: Close holes and openings in building such as broken windows $1,916 $249 $155
4,396
kWh
$1,761
-
MMBtu
-
09 2.4133: Use most efficient type of electric motors $76 $47 $76
1,465
kWh
- -
TOTAL RECOMMENDED $23,097 $8,629 $16,044
309,496
kWh
$7,972
-
MMBtu
$(-919.0)
TOTAL IMPLEMENTED $19,774 $6,769 $16,044
309,496
kWh
$4,649
-
MMBtu
$(-919.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs