| Assessment Year | 1986 |
|---|---|
| Principal Product | HEAT EXCHANGERS |
| NAICS |
n/a
|
| SIC | 3443: Fabricated Plate Work (Boiler Shops) |
| Sales Range | $10 M to 50M |
| # of Employees | 250 |
| Plant Area |
n/a
|
| Annual Production | 750
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $91,650 | 1,939,918 |
kWh
|
$0.047 |
| Natural Gas | $34,678 | 9,408 |
MMBtu
|
$3.69 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,873 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $518 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $116 | $103 |
$116
2,052
kWh
|
- | |
| 02 | 2.7261: Install timers and/or thermostats | $277 | $700 | - |
$277
-
MMBtu
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $125 | $40 |
$125
4,396
kWh
|
- | |
| 04 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $2,104 | $700 |
$1,100
38,687
kWh
|
$1,004
-
MMBtu
|
|
| 05 | 2.7231: Use radiant heater for spot heating | $10,251 | $54,400 | - |
$10,251
-
MMBtu
|
|
| TOTAL RECOMMENDED | $12,873 | $55,943 |
$1,341
45,135
kWh
|
$11,532
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $518 | $843 |
$241
6,448
kWh
|
$277
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs