| Assessment Year | 2003 |
|---|---|
| Principal Product | Newspapers |
| NAICS | 323111: Commercial Printing (except Screen and Books) |
| SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
| Sales Range | $10 M to 50M |
| # of Employees | 450 |
| Plant Area |
121,515
ft2
|
| Annual Production | 36,000,000
pieces
|
| Production Hrs. Annual | 7,280
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $312,892 | 7,468,000 |
kWh
|
$0.042 |
| Electricity Demand | $60,506 | 15,399 |
kW-mo/yr
|
$3.93 |
| Electricity Fees | $69,636 | - |
|
- |
| Natural Gas | $41,947 | 5,370 |
MMBtu
|
$7.81 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $139,159 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,247 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $75,363 | $327,360 |
$47,059
1,412,005
kWh
|
$9,758
-
kW-mo/yr
|
$18,546 | - | - | - | |
| 02 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $34,758 | $50,000 |
$28,156
844,800
kWh
|
- | $6,602 | - | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,550 | $19,555 | n/a |
$12,419
372,640
kWh
|
$1,787
-
kW-mo/yr
|
$3,344 | - | - | - |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,247 | $1,061 |
$3,440
103,221
kWh
|
- | $807 | - | - | - | |
| 05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $3,122 | $300 |
$1,919
57,582
kWh
|
$2,268
-
kW-mo/yr
|
$997 |
$(-2,062.0)
-
MMBtu
|
- | - | |
| 06 | 2.4239: Eliminate or reduce compressed air usage | $1,170 | $371 |
$948
28,438
kWh
|
- | $222 | - | - | - | |
| 07 | 2.3132: Recharge batteries on during off-peak demand periods | $1,381 | - | - |
$1,113
-
kW-mo/yr
|
$268 | - | - | - | |
| 08 | 4.821: Pay bills on time to avoid late fees | $753 | $234 | - | - | - | - | - |
$753
-
Tgal
|
|
| 09 | 2.7134: Use photocell controls | $470 | $222 |
$381
11,426
kWh
|
- | $89 | - | - | - | |
| 10 | 2.2136: Install / repair insulation on steam lines | $297 | $48 | - | - | - |
$297
-
MMBtu
|
- | - | |
| 11 | 4.812: Apply for investment incentives | $48 | $50 | - | - | - | - | $48 | - | |
| TOTAL RECOMMENDED | $139,159 | $399,201 |
$94,322
2,830,112
kWh
|
$14,926
-
kW-mo/yr
|
$30,875 |
$(-1,765.0)
-
MMBtu
|
$48 |
$753
-
Tgal
|
||
| TOTAL IMPLEMENTED | $4,247 | $1,061 |
$3,440
103,221
kWh
|
- | $807 | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs