ITAC Assessment: OK0179
ITAC logo
ITAC Assessment: OK0179
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1985
Principal Product HEAT EXCHANGERS
NAICS
n/a
SIC 3443: Fabricated Plate Work (Boiler Shops)
Sales Range $5
M
to 10
M
# of Employees 50
Plant Area
n/a
Annual Production 300
pieces
Production Hrs. Annual 4,160
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $54,471 1,072,098
kWh
Natural Gas $30,658 8,161
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $14,672 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $13,376

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.3212: Optimize plant power factor $1,296 $3,847 $1,296
-
kWh
-
02 2.7261: Install timers and/or thermostats $271 $600 - $271
-
MMBtu
03 2.7231: Use radiant heater for spot heating $12,890 $4,700 - $12,890
-
MMBtu
04 2.7142: Utilize higher efficiency lamps and/or ballasts $215 $248 $215
5,275
kWh
-
TOTAL RECOMMENDED $14,672 $9,395 $1,511
5,275
kWh
$13,161
-
MMBtu
TOTAL IMPLEMENTED $13,376 $5,548 $215
5,275
kWh
$13,161
-
MMBtu
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs