ITAC Assessment: OK0174
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1985
Principal Product RECIPROCATING PUMPS
NAICS
n/a
SIC 3561: Pumps and Pumping Equipment
Sales Range $10
M
to 50
M
# of Employees 110
Plant Area
n/a
Annual Production 600
pieces
Production Hrs. Annual 5,096
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $82,826 1,689,918
kWh
Natural Gas $21,184 5,559
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $11,579 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,579

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.3212: Optimize plant power factor $980 $2,872 $980
-
kWh
-
02 2.7261: Install timers and/or thermostats $5,711 $1,000 - $5,711
-
MMBtu
03 2.7142: Utilize higher efficiency lamps and/or ballasts $310 $358 $310
8,206
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $4,578 $21,250 $4,578
110,492
kWh
-
TOTAL RECOMMENDED $11,579 $25,480 $5,868
118,698
kWh
$5,711
-
MMBtu
TOTAL IMPLEMENTED $11,579 $25,480 $5,868
118,698
kWh
$5,711
-
MMBtu
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs