Assessment Year | 1985 |
---|---|
Principal Product | PORTA-DRILLING EQUIPMENT |
NAICS |
n/a
|
SIC | 3533: Oil and Gas Field Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
n/a
|
Annual Production | 10,000,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $187,549 | 3,834,994 |
kWh
|
$0.049 |
Natural Gas | $99,208 | 26,904 |
MMBtu
|
$3.69 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $81,093 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $73,908 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $14,817 | - |
$2,295
60,961
kWh
|
$12,522
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $575 | $864 |
$575
9,672
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $485 | $154 |
$485
5,862
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,663 | $2,050 |
$4,663
78,253
kWh
|
- | |
05 | 2.7261: Install timers and/or thermostats | $49,981 | $1,200 | - |
$49,981
-
MMBtu
|
|
06 | 2.7261: Install timers and/or thermostats | $476 | $100 | - |
$476
-
MMBtu
|
|
07 | 2.7261: Install timers and/or thermostats | $2,911 | $600 | - |
$2,911
-
MMBtu
|
|
08 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $5,133 | $2,148 | - |
$5,133
-
MMBtu
|
|
09 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $2,052 | $1,893 | - |
$2,052
-
MMBtu
|
|
TOTAL RECOMMENDED | $81,093 | $9,009 |
$8,018
154,748
kWh
|
$73,075
-
MMBtu
|
||
TOTAL IMPLEMENTED | $73,908 | $4,968 |
$8,018
154,748
kWh
|
$65,890
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs