| Assessment Year | 1985 |
|---|---|
| Principal Product | GASKET & BOLT SETS |
| NAICS |
n/a
|
| SIC | 3053: Gaskets, Packing, and Sealing Devices |
| Sales Range | $1 M to 5M |
| # of Employees | 27 |
| Plant Area |
n/a
|
| Annual Production | 12,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $9,025 | 133,939 |
kWh
|
$0.067 |
| Natural Gas | $4,130 | 852 |
MMBtu
|
$4.85 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,155 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,062 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $60 | - |
$60
879
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $161 | $33 |
$161
2,345
kWh
|
- | |
| 03 | 2.7261: Install timers and/or thermostats | $93 | $100 | - |
$93
-
MMBtu
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $638 | $180 |
$638
9,672
kWh
|
- | |
| 05 | 2.7231: Use radiant heater for spot heating | $1,375 | $76 |
$34
586
kWh
|
$1,341
-
MMBtu
|
|
| 06 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,828 | $3,400 |
$1,749
26,084
kWh
|
$79
-
MMBtu
|
|
| TOTAL RECOMMENDED | $4,155 | $3,789 |
$2,642
39,566
kWh
|
$1,513
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,062 | $3,689 |
$2,642
39,566
kWh
|
$1,420
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs