Assessment Year | 1984 |
---|---|
Principal Product | HEAT EXCHANGER DESIGN |
NAICS |
n/a
|
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $1 M to 5M |
# of Employees | 31 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $11,971 | 195,780 |
kWh
|
$0.061 |
Natural Gas | $1,768 | 389 |
MMBtu
|
$4.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $2,113 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,455 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $344 | $434 |
$344
5,569
kWh
|
- | |
02 | 2.7261: Install timers and/or thermostats | $744 | - | - |
$744
-
MMBtu
|
|
03 | 2.7111: Reduce illumination to minimum necessary levels | $658 | - |
$658
10,844
kWh
|
- | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $367 | - |
$367
6,155
kWh
|
- | |
TOTAL RECOMMENDED | $2,113 | $434 |
$1,369
22,568
kWh
|
$744
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,455 | $434 |
$711
11,724
kWh
|
$744
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs