| Assessment Year | 1983 |
|---|---|
| Principal Product | PORCELAIN WALL PANELS |
| NAICS |
n/a
|
| SIC | 3448: Prefabricated Metal Buildings and Components |
| Sales Range | $10 M to 50M |
| # of Employees | 75 |
| Plant Area |
n/a
|
| Annual Production | 8,000
thousand feet
|
| Production Hrs. Annual | 5,250
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $102,579 | 2,216,882 |
kWh
|
$0.046 |
| Natural Gas | $188,702 | 55,078 |
MMBtu
|
$3.43 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,957 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $22,361 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2443: Re-use or recycle hot or cold process exhaust air | $3,912 | $11,990 | - |
$3,912
-
MMBtu
|
|
| 02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $5,027 | $700 | - |
$5,027
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,117 | $22,000 |
$13,117
325,615
kWh
|
- | |
| 04 | 2.3212: Optimize plant power factor | $596 | $1,640 |
$596
-
kWh
|
- | |
| 05 | 2.7261: Install timers and/or thermostats | $203 | $296 | - |
$203
-
MMBtu
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $102 | $142 |
$102
2,052
kWh
|
- | |
| TOTAL RECOMMENDED | $22,957 | $36,768 |
$13,815
327,667
kWh
|
$9,142
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $22,361 | $35,128 |
$13,219
327,667
kWh
|
$9,142
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs