| Assessment Year | 1983 |
|---|---|
| Principal Product | VENTILATION EQUIPMENT |
| NAICS |
n/a
|
| SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 350 |
| Plant Area |
n/a
|
| Annual Production | 269,843
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $145,017 | 3,296,014 |
kWh
|
$0.044 |
| Natural Gas | $81,653 | 30,105 |
MMBtu
|
$2.71 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,618 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $146 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,954 | $765 |
$9,954
319,168
kWh
|
|
| 02 | 2.4221: Install compressor air intakes in coolest locations | $146 | $99 |
$146
4,689
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,518 | $20,020 |
$3,518
84,115
kWh
|
|
| TOTAL RECOMMENDED | $13,618 | $20,884 |
$13,618
407,972
kWh
|
||
| TOTAL IMPLEMENTED | $146 | $99 |
$146
4,689
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs