Assessment Year | 1983 |
---|---|
Principal Product | LINGERIE |
NAICS |
n/a
|
SIC | 2341: Women's, Misses', Children's, and Infants' Underwear and Nightwear |
Sales Range | $1 M to 5M |
# of Employees | 300 |
Plant Area |
n/a
|
Annual Production | 93,600
pieces
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $30,082 | 544,842 |
kWh
|
$0.055 |
Natural Gas | $11,819 | 3,610 |
MMBtu
|
$3.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,282 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2122: Install / repair insulation on condensate lines | $147 | $250 | - |
$147
-
MMBtu
|
|
02 | 2.7221: Lower temperature during the winter season and vice-versa | $4,400 | $154 |
$1,212
37,515
kWh
|
$3,188
-
MMBtu
|
|
03 | 2.7227: Use water on air conditioning exchanger to improve heat transfer and increase air conditioner efficiency | $806 | $1,825 |
$806
24,912
kWh
|
- | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $345 | $193 |
$121
3,810
kWh
|
$224
-
MMBtu
|
|
05 | 2.7111: Reduce illumination to minimum necessary levels | $196 | $165 |
$196
4,689
kWh
|
- | |
06 | 2.7111: Reduce illumination to minimum necessary levels | $858 | $169 |
$858
19,343
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $530 | $428 |
$530
9,086
kWh
|
- | |
TOTAL RECOMMENDED | $7,282 | $3,184 |
$3,723
99,355
kWh
|
$3,559
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs