| Assessment Year | 1983 |
|---|---|
| Principal Product | NEWSPAPERS |
| NAICS |
n/a
|
| SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
| Sales Range | $1 M to 5M |
| # of Employees | 30 |
| Plant Area |
n/a
|
| Annual Production | 1,716,000
pieces
|
| Production Hrs. Annual | 3,120
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $7,418 | 118,699 |
kWh
|
$0.062 |
| Natural Gas | $969 | 272 |
MMBtu
|
$3.56 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $1,851 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,520 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $331 | $198 |
$331
7,620
kWh
|
- | |
| 02 | 2.7261: Install timers and/or thermostats | $661 | $642 |
$343
7,913
kWh
|
$318
-
MMBtu
|
|
| 03 | 2.7492: Use proper thickness of insulation on building envelope | $437 | $1,445 | - |
$437
-
MMBtu
|
|
| 04 | 2.7226: Use computer programs to optimize hvac performance | $422 | $1,500 |
$422
9,672
kWh
|
- | |
| TOTAL RECOMMENDED | $1,851 | $3,785 |
$1,096
25,205
kWh
|
$755
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,520 | $3,587 |
$765
17,585
kWh
|
$755
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs