| Assessment Year | 1982 |
|---|---|
| Principal Product | FURNITURE WOOD |
| NAICS |
n/a
|
| SIC | 2511: Wood Household Furniture, Except Upholstered |
| Sales Range | $1 M to 5M |
| # of Employees | 60 |
| Plant Area |
n/a
|
| Annual Production | 4,500
pieces
|
| Production Hrs. Annual | 2,125
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $19,100 | 311,841 |
kWh
|
$0.061 |
| Natural Gas | $9,200 | 2,630 |
MMBtu
|
$3.50 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,335 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $106 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,442 | $400 |
$1,442
22,860
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $345 | $156 |
$345
5,569
kWh
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $106 | $205 |
$106
1,758
kWh
|
- | |
| 04 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $972 | - |
$880
14,068
kWh
|
$92
-
MMBtu
|
|
| 05 | 2.7111: Reduce illumination to minimum necessary levels | $2,330 | - |
$2,330
28,136
kWh
|
- | |
| 06 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $140 | - |
$140
2,345
kWh
|
- | |
| TOTAL RECOMMENDED | $5,335 | $761 |
$5,243
74,736
kWh
|
$92
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $106 | $205 |
$106
1,758
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs