Assessment Year | 1982 |
---|---|
Principal Product | AUTO-LEAFSPRINGS |
NAICS |
n/a
|
SIC | 3493: Steel Springs, Except Wire |
Sales Range | $5 M to 10M |
# of Employees | 40 |
Plant Area |
n/a
|
Annual Production | 100,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $7,019 | 126,319 |
kWh
|
$0.056 |
Natural Gas | $16,507 | 5,993 |
MMBtu
|
$2.75 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,548 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,327 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $473 | $283 |
$473
8,206
kWh
|
- | |
02 | 2.7261: Install timers and/or thermostats | $204 | $600 | - |
$204
-
MMBtu
|
|
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $122 | - |
$122
2,052
kWh
|
- | |
04 | 2.7292: Lower ceiling to reduce conditioned space | $230 | $1,137 | - |
$230
-
MMBtu
|
|
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $422 | $500 | - |
$422
-
MMBtu
|
|
06 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $2,097 | $984 | - |
$2,097
-
MMBtu
|
|
TOTAL RECOMMENDED | $3,548 | $3,504 |
$595
10,258
kWh
|
$2,953
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,327 | $2,121 | - |
$2,327
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs