Assessment Year | 1982 |
---|---|
Principal Product | PLASTIC CONTAINERS |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 40 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $33,745 | 624,560 |
kWh
|
$0.054 |
Natural Gas | $3,579 | 1,181 |
MMBtu
|
$3.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,764 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,052 | $58 |
$3,052
106,389
kWh
|
- | |
02 | 2.7261: Install timers and/or thermostats | $3,457 | $800 | - |
$3,457
-
MMBtu
|
|
03 | 2.7226: Use computer programs to optimize hvac performance | $2,901 | $4,000 |
$2,901
88,511
kWh
|
- | |
04 | 2.7421: Reduce glazed areas in buildings | $2,354 | $3,036 |
$1,007
35,170
kWh
|
$1,347
-
MMBtu
|
|
TOTAL RECOMMENDED | $11,764 | $7,894 |
$6,960
230,070
kWh
|
$4,804
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs