Assessment Year | 1982 |
---|---|
Principal Product | HEAVY TRUCK CHASSIS |
NAICS |
n/a
|
SIC | 3531: Construction Machinery and Equipment |
Sales Range | $100 M to 500M |
# of Employees | 500 |
Plant Area |
n/a
|
Annual Production | 1,200
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $243,095 | 7,153,869 |
kWh
|
$0.034 |
Natural Gas | $92,990 | 35,531 |
MMBtu
|
$2.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,253 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $217 | $313 |
$217
6,448
kWh
|
- | |
02 | 2.7231: Use radiant heater for spot heating | $23,027 | $29,970 | - |
$23,027
-
MMBtu
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $259 | $165 |
$259
7,620
kWh
|
- | |
04 | 2.7494: Install storm windows and doors | $4,750 | $17,358 | - |
$4,750
-
MMBtu
|
|
TOTAL RECOMMENDED | $28,253 | $47,806 |
$476
14,068
kWh
|
$27,777
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs