Assessment Year | 1999 |
---|---|
Principal Product | Folding Cartons |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $5 M to 10M |
# of Employees | 37 |
Plant Area |
26,300
ft2
|
Annual Production | 2,000
ton
|
Production Hrs. Annual | 4,400
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $26,789 | 488,863 |
kWh
|
$0.055 |
Electricity Demand | $11,741 | 2,229 |
kW-mo/yr
|
$5.27 |
Electricity Fees | $3,516 | - |
|
- |
LPG | $13,996 | 1,725 |
MMBtu
|
$8.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,126 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,213 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,272 | $14,704 |
$2,531
46,307
kWh
|
$741
-
kW-mo/yr
|
- | |
02 | 2.6231: Utilize controls to operate equipment only when needed | $1,213 | $100 |
$1,213
22,274
kWh
|
- | - | |
03 | 2.7314: Reduce ventilation air | $3,529 | $140 |
$3,529
63,892
kWh
|
- | - | |
04 | 2.7314: Reduce ventilation air | $2,602 | - |
$4,042
73,857
kWh
|
$1,060
-
kW-mo/yr
|
$(-2,500.0) | |
05 | 2.4113: Install motor voltage controller on lightly loaded motors | $510 | $1,870 |
$404
7,327
kWh
|
$106
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $11,126 | $16,814 |
$11,719
213,657
kWh
|
$1,907
-
kW-mo/yr
|
$(-2,500.0) | ||
TOTAL IMPLEMENTED | $1,213 | $100 |
$1,213
22,274
kWh
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs