Assessment Year | 1998 |
---|---|
Principal Product | Wooden Cable Reels |
NAICS |
n/a
|
SIC | 2499: Wood Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 47 |
Plant Area |
40,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,015
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $23,903 | 305,686 |
kWh
|
$0.078 |
Electricity Demand | $5,758 | 1,572 |
kW-mo/yr
|
$3.66 |
Electricity Fees | $5,085 | - |
|
- |
Natural Gas | $5,526 | 695 |
MMBtu
|
$7.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,417 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,417 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,088 | $6,156 |
$1,669
21,395
kWh
|
$419
-
kW-mo/yr
|
|
02 | 2.4133: Use most efficient type of electric motors | $2,251 | $8,135 |
$1,794
22,860
kWh
|
$457
-
kW-mo/yr
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $281 | $490 |
$224
2,931
kWh
|
$57
-
kW-mo/yr
|
|
04 | 2.7135: Install occupancy sensors | $126 | $100 |
$126
1,758
kWh
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,153 | $400 |
$1,153
14,654
kWh
|
- | |
06 | 2.4224: Upgrade controls on compressors | $1,518 | $100 |
$1,518
19,343
kWh
|
- | |
TOTAL RECOMMENDED | $7,417 | $15,381 |
$6,484
82,941
kWh
|
$933
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $7,417 | $15,381 |
$6,484
82,941
kWh
|
$933
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs