| Assessment Year | 1995 |
|---|---|
| Principal Product | peanuts |
| NAICS |
n/a
|
| SIC | 2068: Salted and Roasted Nuts and Seeds |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
70,000
ft2
|
| Annual Production | 40,000
ton
|
| Production Hrs. Annual | 2,040
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $189,809 | 3,049,238 |
kWh
|
$0.062 |
| Natural Gas | $4,677 | 753 |
MMBtu
|
$6.21 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,425 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,575 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4323: Use optimum size and capacity equipment | $12,595 | $4,616 |
$12,595
203,107
kWh
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $752 | $800 |
$752
12,016
kWh
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $823 | $2,967 |
$823
13,482
kWh
|
|
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $261 | $747 |
$261
4,103
kWh
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,994 | $6,431 |
$2,994
48,066
kWh
|
|
| TOTAL RECOMMENDED | $17,425 | $15,561 |
$17,425
280,774
kWh
|
||
| TOTAL IMPLEMENTED | $1,575 | $3,767 |
$1,575
25,498
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs