| Assessment Year | 1995 |
|---|---|
| Principal Product | Special Regulators and Torches |
| NAICS |
n/a
|
| SIC | 3569: General Industrial Machinery and Equipment, Not Elsewhere |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
135,000
ft2
|
| Annual Production | 500,000
pieces
|
| Production Hrs. Annual | 2,338
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $175,950 | 2,876,319 |
kWh
|
$0.061 |
| Natural Gas | $16,681 | 2,956 |
MMBtu
|
$5.64 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,483 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,993 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $5,570 | $75 |
$5,570
52,755
kWh
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,583 | $800 |
$1,583
25,791
kWh
|
- | |
| 03 | 2.7135: Install occupancy sensors | $1,789 | $1,374 |
$1,789
29,015
kWh
|
- | |
| 04 | 2.2437: Recover waste heat from equipment | $1,788 | $1,447 | - |
$1,788
-
MMBtu
|
|
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $410 | $396 |
$410
6,741
kWh
|
- | |
| 06 | 2.6232: Install set-back timers | $1,343 | $1,075 | - |
$1,343
-
MMBtu
|
|
| TOTAL RECOMMENDED | $12,483 | $5,167 |
$9,352
114,302
kWh
|
$3,131
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,993 | $1,196 |
$1,993
32,532
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs