Assessment Year | 1995 |
---|---|
Principal Product | Tobacco and Food Processing Machinery |
NAICS |
n/a
|
SIC | 3556: Food Products Machinery |
Sales Range | $5 M to 10M |
# of Employees | 85 |
Plant Area |
87,000
ft2
|
Annual Production | 360
pieces
|
Production Hrs. Annual | 4,250
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $85,962 | 1,167,351 |
kWh
|
$0.074 |
Natural Gas | $26,925 | 5,020 |
MMBtu
|
$5.36 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $52,454 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $44,807 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $41,283 | $67,113 |
$41,283
560,961
kWh
|
- | |
02 | 2.7261: Install timers and/or thermostats | $6,341 | $1,560 | - |
$6,341
-
MMBtu
|
|
03 | 2.7261: Install timers and/or thermostats | $2,461 | $1,365 |
$172
2,345
kWh
|
$2,289
-
MMBtu
|
|
04 | 2.4133: Use most efficient type of electric motors | $245 | $272 |
$245
3,224
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $387 | $292 |
$387
5,275
kWh
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $676 | $500 |
$676
9,086
kWh
|
- | |
07 | 2.1223: Install smaller boiler (increase high fire duty cycle) | $1,061 | $610 | - |
$1,061
-
MMBtu
|
|
TOTAL RECOMMENDED | $52,454 | $71,712 |
$42,763
580,891
kWh
|
$9,691
-
MMBtu
|
||
TOTAL IMPLEMENTED | $44,807 | $69,270 |
$42,518
577,667
kWh
|
$2,289
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs